optoNCDT 240x - In-Focus Displacement and Position Measurement
optoNCDT 2401 are confocal displacement sensors for extremely precise applications. Polychromatic light (white light) is used for measuring. The sensors are available in standard and worldwide unique miniaturized design. The standard sensors, series IFS 2400 and IFS 2401, are applicable for usual measurements and also for one-sided thickness-measurement. The miniaturized sensors IFS 2402, with only 4 mm outer diameter and titan housing, are used within narrow cavities or drill holes.
|
|
|
Special characteristics:
|
|
Extreme small and constant spot size
|
|
Target independent - best accuracy against mirror and glass surface
|
|
Nanoresolution
|
|
One-sided thickness-measurement
|
|
Axial and radial version
|
| Overview |
Measuring range |
Resolution |
Linearity |
Frequency response |
| optoNCDT 1300 |
20 ... 200 mm |
0,02 % FSO |
<± 0,2 % FSO |
500 Hz |
| optoNCDT 1401 |
5 ... 250 mm |
0,01 % FSO |
<± 0,2 % FSO |
1 kHz |
| optoNCDT 1607 |
0,5 ... 200 mm |
0,03 % FSO |
<± 0,2 % FSO |
37 kHz |
| optoNCDT 1700 |
2 … 750 mm |
0,005 % FSO |
<± 0,08 % FSO |
2,5 kHz |
| optoNCDT 2200 |
2 ... 200 mm |
0,0015 % FSO |
<± 0,03 % FSO |
10 kHz |
| optoNCDT 2220 |
2 ... 200 mm |
0,0015 % FSO |
<± 0,03 % FSO |
20 kHz |
| optoNCDT 2401 |
0,12 … 25 mm |
0,004 % FSO |
<± 0,05 % FSO |
2 kHz |
| optoNCDT ILR |
0,2 - 250 m |
- |
± 10 mm |
- |
FSO = full scale output
Downloads for laser sensors
| Product |
Data sheet |
Manual |
Software |
CAD |
|